AC Tripping the Circuit Breaker: Know the Reason Why?

A breaker-tripping air conditioner should never be ignored. There is a problem, and it will not likely resolve itself. A circuit breaker typically trips due to an excessive current draw from a circuit component. The air conditioner may sustain costly, long-lasting damage as a result. It is wise to call a skilled professional for air conditioning repair on Palm Coast.

Causes of the AC Circuit Breaker Trip

  • Lightning Strike

At the thermostat, switch the air conditioning system OFF, and after a few minutes, turn it ON. For example, a one-time power surge can occasionally be brought on by nearby lightning strikes. Set your air conditioner back to COOL after 30 minutes.

  • Obstructed Air Filter

The fan motor must work harder and run longer to draw air through a system filter that is clogged with dust and debris. It might try to accomplish this by drawing too much electricity, which would trip the AC circuit breaker.

  • Unclean Condenser Coil

Have you noticed that your air conditioner doesn’t operate as well as it once did? A possible cause could be a dirty condenser coil. A condensing coil in your outdoor air conditioner does the job of dispersing built-up heat outside your structure. Due to its exposure, the elements may become covered in dirt and debris, hindering heat transfer. Call a specialist for HVAC services in Daytona Beach.

  • A Broken Fan Motor

The fan may have dirty blades slowing it down and straining the motor. Or, the issue could stem from the motor’s internal malfunction. For this issue, your AC service technician will need to swap out the fan motor during HVAC services in Ormond Beach, FL.

  • Frozen Evaporator Coil

This happens if you notice ice on the coils of your indoor air conditioning unit. If you have neglected maintenance for a long time and have several issues mentioned above, your system’s airflow will eventually decrease. So, the evaporator coil may freeze and draw too much power, tripping the AC circuit breaker.

  • Failure of an Electrical Component

A straightforward electrical problem with the air conditioner may cause a power surge that trips the AC circuit breaker. Possible causes include a faulty capacitor, a loose connection, or wiring short. An HVAC service in Daytona beach professional can efficiently resolve those problems.

  • Compressor Malfunction

Your air conditioning system’s compressor is its engine, so if it breaks down, you might need to replace the entire unit. Because of this, you must never restart the AC circuit breaker after it trips or disregards any of the above mentioned issues. The failure of the compressor is a costly outcome that may eventually result from the system’s stress.

  • Leaked Refrigerant

An older air conditioner may experience corrosion, which results in cracks, holes, and refrigerant leaks. Your system must work harder and run longer to cool your space as the refrigerant level drops. Any refrigerant leaks must be located and fixed by your HVAC services in Ormond Beach, FL technician. Replace the coil and the refrigerant lines if there are many.

Conclusion

Let Accu-Temp Heating & Air Conditioning assist you if your AC circuit breaker keeps tripping or if you are experiencing other heating or cooling issues. Call us at 386-244-9440 or send us a mail any time, day or night, and we’ll take care of air conditioning repair!

Get A Quote